Form Wash & Cure
Form Wash & Cure | |
---|---|
Name | Form Wash & Cure |
Zone | Fab Lab
|
Owner | Paul Frick |
Make Model | FormLabs Wash, FormLabs Cure |
Part Number | Wash - InventiveCria, Cure - InventiveGrebe |
Date Acquired | 05/29/21 |
Storage Location | FabLab |
Authorization Required | Yes |
Status | Running |
Value | $1100
|
Power Requirements | 120VAC |
Documentation | https://formlabs.com/post-processing/wash-cure/ |
Other References |
Contents
Intro
More automated way to clean and cure resin prints, specifically needed for engineering resins (anything except the Gray v4 that we have a lot of).
Rules
1. Keep equipment clean and tidy, wipe down tools with IPA after use and keep tools in storage compartments on back of Form Wash.
2. Lower basket of Form Wash into fluid and close top lid when not in use.
3. Keep lid of Form Cure closed when not in use.
Instructions
Recommended Workflow:
- To be started following completion of print on Form2 or other resin printer
1. Press button on front of Form Wash (left side of bench, next to Form2 printer) to wake, select "Open" in the menu 2. Wait for basket to rise from the fluid bath 3. Remove parts from bed of resin printer, place in wash basket 3. Select second line of menu and adjust wash time 4. Select "Start" to lower the basket into the wash fluid and start the wash cycle
5. Once wash cycle is complete, basket should raise out of the fluid
6. Remove parts from basket 7. Select "Sleep" to lower basket back into fluid to minimize fluid loss
8. Allow parts to air dry on a paper towel until most IPA is evaporated
9. Open lid of Form Cure (right side of bench) 10. Place parts on wire mesh turntable, spaced so that all sides can be exposed to the UV cure light. Multiple cure sessions may be needed if there are more parts than can fit on the turntable comfortably 11. Press button on front of Form Cure to wake from sleep 12. Set cure time and cure temperature in menu 13. Close lid of Form Cure 14. Select "Start" to start UV heated cure
15. Once cure cycle is complete, open lid and remove parts 16. Close lid
Maintenance Info
Periodically check cloudiness of IPA bath in Form Wash. Use hydrometer (stored in tool compartment on right rear side of the Form Wash) to check quality of IPA, red o-ring should be at or close to water-line. If o-ring is well above the water-line, IPA needs to be changed out.
FAQ
ToDo
Find wash/cure time/temperature table for resins
Authorized Users and Trainers
Trainer Name | Certified Date
|
---|
User Name | Authorized By | Date of Most Recent Training |
---|---|---|
Ben Wilk | Paul Frick | 2022.04.09 |
Paul Lee | Paul Frick | 2023.05.09 |