Intro
esp8266 based thermostat
KiCad project schematics and board layout: https://github.com/i3detroit/custom-mqtt-programs/tree/master/thermostat/thermostat Source: https://github.com/i3detroit/custom-mqtt-programs/tree/master/thermostat
Rules
Instructions
- This will only display temperatures in Celsius, this is by design
- There is no way to forget to set the thermostat back to 'run' as there is no 'hold' button, the thermostat will revert to the default state after three hours of no one touching it. This is by design.
- The switches that are normally present on a thermostat (fan on/fan auto ; heat/off/cool) have been replaced with buttons and green LEDs to indicate the mode.
Maintenance Info
FAQ
ToDo